Anzeige
HANNOVER MESSE 2018, 23. - 27. April
Aussteller 2018

Microcyber

Logo Microcyber

Kontakt­daten

Microcyber Corporation

17-8 Wensu Street
Hunnan New District
110179 Shenyang
China
E-Mail senden
Fax: +86 24 31217293

Ansprech­partner

Frau Tieying Zhang
E-Mail senden
Telefon: +86 24 31217280
Fax: +86 24 31217279

Fakten

Unternehmensart
Hersteller

Gründungsjahr
2003

Anzahl Mitarbeiter
101-250 (Stand: 2003)

Produkte

G1100 WirelessHART Gateway

Microcyber G1100 WirelessHART smart gateway is in charge of establishment, management and maintenance of WirelessHART network, and network optimization, to make the devices in the network work in the effective and safe situation. Meanwhile, WirelessHART smart gateway integrates device data information ...weiterlesen

M0307 Modbus to PA Module

M0307 realizes the conversion function from Modbus RTU Protocol to PROFIBUS PA Protocol. It connects the slave device with Modbus RTU protocol to PROFIBUS PA network. The M0307 module is the only PROFIBUS PA device that can realize this function in China. All the related configuration is realized through ...weiterlesen

M0306 Modbus to DP Module

Modbus-DP built-in module realizes the connection from Modbus RTU device to PROFIBUS DP network .It realizes the conversion function from MODBUS Protocol to PROFIBUS DP Protocol. Only by simply operating Modbus configuration tool, the users can realize connection from Modbus RTU device to PROFIBUS DP ...weiterlesen

M0310 MODBUS to HART Built-in Module

convert Modbus RTU protocol directly to HART protocolweiterlesen

M1100 WirelessHART Module

Microcyber's M1100S WirelessHART module can help device manufacturer to realize simple and rapid integration of WirelessHART communication standard into field device, to achieve safe, reliable and standard WirelessHART data transmission, to improve product's performance and competitive force.weiterlesen

APC3 DP Communication Controller

Compatible with VPC3 in mode DPV0, at the working voltage 3.3V Compatible with SPC3 in mode DPV0, except for different the working voltages Support Intel and Motorola processing interface modesweiterlesen

G0313 Modbus to FF Gateway

Provide FF H1 communication ability to Modbus device Support standard DD or EDD specification (FF H1) Electrical interface connected with Modbus device supports TTL level, RS485 and RS232weiterlesen

G0306 Modbus to DP Gateway

>MODBUS-RTU master station, comply with MODBUS-RTU protocol >Electrical interface connected with Modbus device supports TTL level >Set MODBUS-RTU slave station via parameters provided by GSD fileweiterlesen

G0310 Modbus to HART Gateway

>Compliant with HART 6.0 standard, provide HART communication ability to Modbus device >Support 375/475 handheld device >Electrical interface connected with Modbus device supports TTL level, RS485 and RS232weiterlesen

HT1200M HART Communication Controller

Features: - Low power consumption, HT1200M is used for developing HART products and good at performance, cost and quality etc. - HT1200M is compatible with HT20C15 and SYM20C15. - Single chip, FSK modem (Semi-duplex 1200b/s) - Integrates circuit of receiving band-pass filter - External connection ...weiterlesen

NCS-IF105 Current/Fieldbus Converter

As transition device, NCS-IF105 converter can receive 4~20mA analog signal of 4 channels and transfer to FF fieldbus signal. Features: - Number of channels: 4 - Input of signal: 0?20mA, 4?20mA - Input impedance: 50? - Bus signal: 31.25kbit/s - Power: 9VDC?32VDC - Current consumption (static)??20mAweiterlesen

Fieldbus Temperature Transmitter

NCS-TT105 temperature transmitter is a new generation of intelligent transmitter with FF, PROFIBUS PA or HART technology. NCS-TT105 transmitter integrates abundant function block and realizes not only normal measurement function, but also complicated control strategy. Features: - Number of channels: ...weiterlesen

NCS-CONFIG Configuration Software

NCS-Config Configuration Software is able to detect fieldbus device automatically, and has the functions such as network configuration, control loop configuration, control logic configuration, function block connection, alarm trend, control appliance download, etc. Features: - Complied with FF H1, ...weiterlesen

NCS-VIEWER Monitoring Configuration Software

Features: - Visible development environment - Complied with OPC Standard, able to develop customized OPC Server for users - Complied with VB Script Language, make user self-programmable and able to develop flexible complicated appliance - Compatible to the 3rd ActiveX Control - Powerful historical ...weiterlesen

Network Control System - NCS4000

NCS4000 System is a Networked Control System. It can be used in the industrial control environment of large and middle scale, and provides process control, logic control, batch control and other advanced control functions. It is widely used in metallurgy, petrol, chemical, power, cement, water treatment ...weiterlesen

FBC0409 Fieldbus Communication Controller

- Designed to comply with IEC 61158-2 - Has physical layer and some function of link layer - Good at integration, simple external circuit, small size - Available in 44-pins TQFP package - Internal 4k bytes asynchronous SRAM storage data for transmitting, ...weiterlesen

NCS-RC105H HART Communication Board

NCS-RC105H HART communication board is developed with HART protocol. It becomes the digital field device combined with conventional instruments, so it can be used as HART or 4-20mA instrument. NCS-RC105H HART communication board provides the function of control, capture/output and display for field device. Features ...weiterlesen

NCS-RC105 FF H1

NCS-RC105 FF H1/PA Communication Board is developed with the FF and Profibus PA protocol. As the core module of intelligent instruments, NCS-RC105FF H1 provides the function of control, capture/output and display for field device. NCS-RC105FF H1 can be the Link Master or Slave device and provide abundant ...weiterlesen

NCS-PT105

As a new generation of smart fieldbus pressure transmitter, NCS-PT105 series smart pressure transmitter has a capacitance sensor optimized for pressure measurement. It is available on FF H1 Profibus PA and HART protocol. This transmitter has high accuracy, better reliability and intrinsically safety. NCS-PT105 ...weiterlesen

Auf der Merkliste

0

Das Merken ist fehlgeschlagen, da ein Problem mit der Verbindung zum Server aufgetreten ist.