Produkte

Miniature sensors, coils and inductors

21 Models, Capacity for toroidal is 70000/Month and for Coils is 12000/Month.weiterlesen

Bushing current Transformers for GIS, HV breakers & Power

Over 500 Models, Capacity 2500/Month and plastic cased, taped, resin castedweiterlesen

Low voltage Current & Voltage Transformers

- Plastic cased, resin casted, tape insulated - 300 Models, Capacity 45000/monthweiterlesen

Current and Voltage Transformers for bus duct application

- Resin casted or tape insulated - 8 Models, Capacity 450/Monthweiterlesen

Medium voltage Current and Voltage Transformers

Here you cann see the medium coltage current and coltage transformers. See the Indoor-resin cast, panel mounted and Outdoor-resin cast or oil insulated - 40 Models, Capacity 4000/month for resin cast and 350/month for oil insulatedweiterlesen

Current & Voltage Transformers for MV switchboard application

In this product you can see up to 36 kV system voltage (36/70/170kVp) - Primary current rating up to 6,000 Amps for CTs - Type tested for STC rating up to 50kA, 3 second - Secondary current rating of 1 Amps, 5 Amps, 0.577 Amps (or any relay feed current value) or custom specified. -Secondary voltage ...weiterlesen

Current Transformers for LV switchborad application

In this product you can have a look at current transformers for LV switchboard application. A Primary current rating up to 5,000 Amps - Secondary current rating of 1 Amps, 2 Amps, 5 Amps, 0.577 Amps (or any relay feed current value) or custom specified - Burden value up to 50 VA (IEC 60044, IS 2705) - ...weiterlesen

Current Transformers for Air circuit breaker application

In the air circuit breaker application you can find a Primary current rating up to 9,000 Amps and secondary current rating of 1 Amps, 2 Amps, 5 Amps, 0.577 Amps (or any relay feed current value) or custom specified - Suitable to thermal and static relays - Burden suitable for CT release combination - ...weiterlesen

Current Transformers for Power Transformer application

In this product you will find a Primary current rating up to 20,000 Amps - Secondary current rating of 1 Amps, 2 Amps, 5 Amps, 0.577 Amps (or any relay feed current value) or custom specified - Burden and accuracy class to meet Metering (eg. 15VA Class 0.2), Protection (eg. 50VA 5P40) and Special protection ...weiterlesen

Current Transformers for Energy meter application

In this product you will find Primary current up to 200 Amps and DC immunity. Aswell as Inner diameter up to 7 mm, turn ratio up to 5000:1 and many more like: - Typical linearity as per class 0.2S, 0.5S, 0.1 - Option of geometry to customer needs - Designed for easy electronic interface - Can be ...weiterlesen