Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Exhibitor 2017

Microcyber

Fieldbus Solution with Microcyber

Logo Microcyber
Exhibition stand
(Main stand)

Company Data

Microcyber Corporation

17-8 Wensu Street
Hunnan New District
110179 Shenyang
China
Send E-mail
Fax: +86 24 31217293

Contact(s)

Ms. Tieying Zhang
Send E-mail
Fax: +86 24 31217279

Facts

Type of company
Manufacturer

Year founded
2003

No. of employees
101-250 (Status: 2003)

Company profile

As one of leading supplier of fieldbus products, Microcyber Corporation mainly provides communication stack, communication controller chip (FF, PROFIBUS and HART), customized communication board (FF, PROFIBUS and HART), control configuration software, control system -- NCS4000 System, pressure transmitter with capacitance sensor or diffused silicon sensor (FF, PROFIBUS and HART), temperature transmitter (FF, PROFIBUS and HART) and F/I & I/F converter, etc..

Microcyber has a lot of experience in providing fieldbus products and realizes FF/PROFIBUS/HART communication boards by using different firmware in same hardware. Also Software outsourcing is available for manufacturers. Microcyber`s pressure transmitter, linking device and F/I & I/F converter have been registered in Fieldbus Foundation.

Company website

Products

M0310 MODBUS to HART Built-in Module

convert Modbus RTU protocol directly to HART protocolread more

M1100 WirelessHART Module

WH-M WirelessHART module is a wireless communication module compliant with HART7.4 protocol, and is the core part of WirelessHART field device. WH-M periphery provides TTL serial port and control interface. Fast and low risk integration Low power consumption WirelessHART compliance Support protocols ...read more

APC3 DP Communication Controller

Compatible with VPC3 in mode DPV0, at the working voltage 3.3V Compatible with SPC3 in mode DPV0, except for different the working voltages Support Intel and Motorola processing interface modesread more

G0313 Modbus to FF Gateway

Provide FF H1 communication ability to Modbus device Support standard DD or EDD specification (FF H1) Electrical interface connected with Modbus device supports TTL level, RS485 and RS232read more

G0306 Modbus to DP Gateway

>MODBUS-RTU master station, comply with MODBUS-RTU protocol >Electrical interface connected with Modbus device supports TTL level >Set MODBUS-RTU slave station via parameters provided by GSD fileread more

G0310 Modbus to HART Gateway

>Compliant with HART 6.0 standard, provide HART communication ability to Modbus device >Support 375/475 handheld device >Electrical interface connected with Modbus device supports TTL level, RS485 and RS232read more

HT1200M HART Communication Controller

Features: - Low power consumption, HT1200M is used for developing HART products and good at performance, cost and quality etc. - HT1200M is compatible with HT20C15 and SYM20C15. - Single chip, FSK modem (Semi-duplex 1200b/s) - Integrates circuit of receiving band-pass filter - External connection ...read more

NCS-IF105 Current/Fieldbus Converter

As transition device, NCS-IF105 converter can receive 4~20mA analog signal of 4 channels and transfer to FF fieldbus signal. Features: - Number of channels: 4 - Input of signal: 0?20mA, 4?20mA - Input impedance: 50? - Bus signal: 31.25kbit/s - Power: 9VDC?32VDC - Current consumption (static)??20mAread more

Fieldbus Temperature Transmitter

NCS-TT105 temperature transmitter is a new generation of intelligent transmitter with FF, PROFIBUS PA or HART technology. NCS-TT105 transmitter integrates abundant function block and realizes not only normal measurement function, but also complicated control strategy. Features: - Number of channels: ...read more

NCS-CONFIG Configuration Software

NCS-Config Configuration Software is able to detect fieldbus device automatically, and has the functions such as network configuration, control loop configuration, control logic configuration, function block connection, alarm trend, control appliance download, etc. Features: - Complied with FF H1, ...read more

NCS-VIEWER Monitoring Configuration Software

Features: - Visible development environment - Complied with OPC Standard, able to develop customized OPC Server for users - Complied with VB Script Language, make user self-programmable and able to develop flexible complicated appliance - Compatible to the 3rd ActiveX Control - Powerful historical ...read more

Network Control System - NCS4000

NCS4000 System is a Networked Control System. It can be used in the industrial control environment of large and middle scale, and provides process control, logic control, batch control and other advanced control functions. It is widely used in metallurgy, petrol, chemical, power, cement, water treatment ...read more

FBC0409 Fieldbus Communication Controller

- Designed to comply with IEC 61158-2 - Has physical layer and some function of link layer - Good at integration, simple external circuit, small size - Available in 44-pins TQFP package - Internal 4k bytes asynchronous SRAM storage data for transmitting, ...read more

NCS-RC105H HART Communication Board

NCS-RC105H HART communication board is developed with HART protocol. It becomes the digital field device combined with conventional instruments, so it can be used as HART or 4-20mA instrument. NCS-RC105H HART communication board provides the function of control, capture/output and display for field device. Features ...read more

NCS-RC105 FF H1

NCS-RC105 FF H1/PA Communication Board is developed with the FF and Profibus PA protocol. As the core module of intelligent instruments, NCS-RC105FF H1 provides the function of control, capture/output and display for field device. NCS-RC105FF H1 can be the Link Master or Slave device and provide abundant ...read more

NCS-PT105

As a new generation of smart fieldbus pressure transmitter, NCS-PT105 series smart pressure transmitter has a capacitance sensor optimized for pressure measurement. It is available on FF H1 Profibus PA and HART protocol. This transmitter has high accuracy, better reliability and intrinsically safety. NCS-PT105 ...read more

Stored items

0

Server communication error: Item could not be saved.