Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Homepage>Exhibitors & Products >AmpereSoft TemperatureCalculator

AmpereSoft TemperatureCalculator

Verifications of heating according to DIN EN 61439-1

AmpereSoft

Exhibitor details
Logo AmpereSoft TemperatureCalculator

Exhibition stand
Topic: Joint Pavillion Young & Innovative Digital Factory

Product description

With the CAE independent and cross-manufacturer AmpereSoft TemperatureCalculator you produce standard-compliant proofs for the warming in the switchgear according to DIN EN 61439-1 (IEC 61439-1).

In DIN EN 61439-1 it is distinguish between two calculation methods:
10.10.4.2 System rated current (InA) lower-equal 630A comparison of the cabinet heat loss ability to the at the same time effective, installed power loss.
10.10.4.3 System rated current (InA) lower-equal 1600A temperature calculation (according IEC 60890)
TemperatureCalculator covers both calculation methods by the possibility to create and manage electrical circuit and location structure.

By simply import of your Excel file, material data of a parts list are automatically compared with the MatClass material databases and the calculation relevant data from the standardized eCl@ss ADVANCED structure of the manufacturer databases, and are taken over into the TemperatureCalculator as well as the structure of installation, location and electrical circuit. Your calculation possibility is completed by the integration of your own material data in the databases.

A significant part of the warming in the switchgear is caused by the wiring. This information is implemented and considered in the calculation.

In the TemperatureCalculator the following objects with their properties are distinguished: Switchgear assembly, Cabinet, Device, Busbar, Cable, Wire, Terminal Strip, Terminal.

Only by an equipment-related and load-dependent calculation with provable data (source), a real flawless proof of the warming in the switchgear assembly can be produced. The TemperatureCalculator guarantees this with its detailed calculation and the output of an automatically generated proof document including equipment list!

The warming calculation tool TemperatureCalculator thus makes a key contribution to the smooth running of your process chain.

Product website

All products offered by this exhibitor

DataServices

Product data getting sharpread more

AmpereSoft MatClass

Your optimized engineering process: As an independent material and performance catalog system, MatClass is the decisive contribution to the smooth running of the processes in your company. The detailed technical information in the eCl@ss Advanced structure describes a product so precisely that tasks ...read more

AmpereSoft Configurator

Switchgear & Component configuration, simple_fast_accurate.read more

AmpereSoft QuotationAssistant

The QuotationAssistant supports you by the quick preparing of quotations as well as of tenders; balanced to the demands of the electrical industry. The extensive functions allow the quick preparing of simple quotations up to the calculation of extensive tenders. Use the helpful import function for ...read more

AmpereSoft ProPlan

The user-friendly CAE system for your electrical documentation.read more

AmpereSoft RoutingAssistant

Your CAE independent routing systemread more

AmpereSoft TemperatureCalculator

With the CAE independent and cross-manufacturer AmpereSoft TemperatureCalculator you produce standard-compliant proofs for the warming in the switchgear according to DIN EN 61439-1 (IEC 61439-1). In DIN EN 61439-1 it is distinguish between two calculation methods: 10.10.4.2 System rated current (InA) ...read more

Stored items