Advertisement
HANNOVER MESSE 2018, 23 - 27 April

Cable Gland

HUGRO-Armaturen

Exhibitor details
Logo Cable Gland

Exhibition stand

Hall 12, Stand E03

Product description

EMC Cable Gland with 2 contacting methods - Method 1
1. Screw in the complete cable gland
(5 parts) into the intended housing without
further tightening the compression nut.
2. Partially strip the outer cable sleeve
or trim to the desired length.
3. Feed cable into the cable gland until the
shielding snaps into the contact disk (5)
or the cable sheath contacts the disc.
4. Tighten compression nut (1) to the lower
gland part until the sealing insert forms
a small ridge between the compression
nut an the cable.
FINISHED
If needed, the skinned cable may be pulled
back through the contact disc. - Method 2
The Progress-EMV-RAPID can also
be mounted by extruding the contact disc
(5) without extending the shield.
1. Screw the lower part (4) of the cable
gland into the housing.
2. Push compression nut (1), sealing insert
(2) and contact bushing (3) over the cable.
3. Trim outer sheath of the cable to the
desired length.
4. Trim braided shield or shielding foil to
the the approximate length of contact
bushing X.
5. Push contact bushing, sealing insert
and compression nut to the end of the
sheath.
6. Place braided shield (6) or shielding foil
over the contact bushing and cut off the
protruding shielding material.
7. Feed cable through the already mounted
lower part of the cable gland.
8. Insert sealing insert and contact bushing
flush into the lower part.
9. Tighten compression nut to the lower part
until the sealing insert forms a small ridge
between the compression nut and the
cable. - Characteristics:
- quick installation of partially stripped cables
as well as thoroughly shielded cables
- easy and quick shield terminating
- 1 cable gland, 2 contacting methods

Product website

All products offered by this exhibitor

Flanged Entry Angles

Material: PA (UL-94 VO) halogene free, silicone free Colour: black Temperature range: -20 °C to 80°C Protection type: IP 54read more

Blind Plates (Covers) made of metal or plastic

BM16 Stahl verzinkt / Steel galvanized 763.1600.BM BM24 Stahl verzinkt / Steel galvanized 763.2400.BM BP16 Polyamid / Polyamide 763.1600.BP BP24 Polyamid / Polyamide 763.2400.BPread more

Cable Entry Plates

Material: PA (UL-94 VO) halogene free, silicone free Colour: black Gasket: NBR Temperature range: -20 °C to 80°C Protection type: IP 54 Installation: The cable entry plates has to be fitted with the pre-fabricated cables, the correct grommets must be placed around the cable and inserted into ...read more

Cable Gland

EMC Cable Gland with 2 contacting methods - Method 1 1. Screw in the complete cable gland (5 parts) into the intended housing without further tightening the compression nut. 2. Partially strip the outer cable sleeve or trim to the desired length. 3. Feed cable into the cable gland until the shielding ...read more

Kabelschutzschläuche

Auf den Kabelschutz zugeschnittene Schutzschläuche mit Schlauchverschraubungen, basierend auf dem metrischen und US-Zoll-System, sowohl für Standard-, Liquid Tight- als auch EMV-gerechte Installationen und Anwendungen im Ex-Bereich. Liquid Tight-Kabelschutzschläuche - Anschlussteile - Kunststoffschutzschläuche ...read more

Stored items

0

Server communication error: Item could not be saved.