Product description

The power series of EGE busducts can handle up to 25 kA for self-cooled IPBs and 50 kA for forced cooled IPBs as follows:

Isolated phase busducts (IPB) with air insulation
This type of duct is used primarily for the outlet of generator outputs at current levels as high as 28kA and voltages of 36kV. The basic principle of the busducts' arrangement enables magnetic field radiation to be reduced to below 5%, as well as contributing to simplified handling and minimising potential interruptions for maintenance.

Isolated phase busducts (IPB) with forced cooling
This type of busduct is used for the outlet of generator outputs at current levels of up to 40kA and voltages of 36kV. Cooling can be in the form of air sucked directly in from the environment surrounding a generator or via a cooling unit. The basic principle of the busducts' arrangement enables magnetic field radiation to be reduced to below 5%. Moreover, their simplicity is unique when it comes to replacing insulators or fixing them onto steel structures.

Isolated phase busducts (IPB) of internal consumption
Busducts such as these are primarily used for transmitting outputs between a unit auxiliary transformer and a switching station. They prove both maintenance free and space saving due to their exceptional design, which features a single insulator. In some cases, they can even be used for the outlet of generator outputs at short circuit ratios rated up to Ipeak=125kA and Ith=50kA/1s.

Product website

All products offered by this exhibitor

Three - Phase shunt reactor

TKFC - 3-Phase shunt reactors are used to compensate the reactive power. With the development of renewable electric power sources (above all offshore and land wind farms) the compensation of reactive power gains more significance. TKFC - 3-Phase shunt reactors are disgned for the fixed value of the reactive ...read more

Lattice towers 22 kV - 400 kV

EGE Steel Structures Catalogueread more

Earthing transformers - ETR

ETR earthing transformers are used to create an artificial neutral in distribution electric networks. Typical parameters of EGE ETR earthing transformers are networks of 6, 10, 15, 20, 35 kV and rated power from 200 to 5000 kVA wiring scheme Zn, ZNyn 11 or other variants based on customer's wishes.read more

Earthing resistors for HV networks

Earthing resistors serve connections between the neutral points of distribution network to grounds in networks operating with resistor-grounded neutral points. The purpose of the resistor-grounded neutral is to dampen overvoltage during ground faults and provide sufficient current values for protection, ...read more

Auxiliary resistors

Resistors for increasing active components of fault current. Secondary resistors are used In order to improve the reliability of ground-fault directional protection instruments. The resistors enable active components of the fault current to be increased for a short time. The connection is either controlled ...read more

Ground fault arc suppression coil

Arc suppression coils are used to compensate for capacitive currents when ground faults occur on an electrical network. They are connected to the distribution network node. EGE's arc suppression coils are smoothly adjustable arc suppression coils covering: nominal network voltages from 6 kV to 110 kV ...read more

Isolated Phase Busduct (IPB)

The power series of EGE busducts can handle up to 25 kA for self-cooled IPBs and 50 kA for forced cooled IPBs as follows: Isolated phase busducts (IPB) with air insulation This type of duct is used primarily for the outlet of generator outputs at current levels as high as 28kA and voltages of 36kV. ...read more