Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Homepage>Exhibitors & Products >Lattice towers 22 kV - 400 kV

Lattice towers 22 kV - 400 kV

Logo Lattice towers 22 kV - 400 kV
Logo Lattice towers 22 kV - 400 kV
Logo Lattice towers 22 kV - 400 kV
Logo Lattice towers 22 kV - 400 kV
Logo Lattice towers 22 kV - 400 kV

Exhibition stand

Hall 13, Stand B80

Contact(s)
Mr. Hynek Falta 013 E30
Steel Structures Division Manager
Send E-mail

Product description

22 kV lattice towers
These are steel lattice structures welded together from rolled equal angles, the surface of which is protected by coating or hot dip galvanizing. The series ranges from 12 kN to 80 kN in vertex traction and from 12 to 24 m in height. The towers are fitted with the design of brackets required by our clients.

Lattice towers - 1x110 kV, 2x110 kV and 4x110 kV
Steel lattice structures of rolled equal angles, either fully bolted together or partially so in combination with welded sections. The surface of these items is protected by hot galvanisation or a suitable alternative coating. This series is divided into subgroups of specific applications, i.e. support, tension, anchor, branch or underpass towers.

Lattice towers 220 kV
Steel lattice structures made from rolled equal angles usually bolted together, although a welded version is available. The surface of these items is protected by hot galvanisation or a suitable alternative coating. This series comprises support, tension, anchor and branch towers or portals.

Lattice towers - 1x400 kV, 2x400 kV and 3x400 kV
Lattice structures fully bolted together from rolled equal angles. The surface of these items is protected by hot galvanisation or a suitable alternative coating. The range is divided up according to specific application - support, tension, anchor and branch towers.

Towers for emergency outage (bypasses)
EGE is producer of steel towers for emergency outage - bypasses. These steel structures are delivered on site in case of emergency for 110 - 400 kV. Bypasses are welded parts of rolled angles which can be easily bolted together. The surface of these items is protected by hot galvanisation or a suitable alternative coating.

Product website

Product categories

All products offered by this exhibitor

Three - Phase shunt reactor

TKFC - 3-Phase shunt reactors are used to compensate the reactive power. With the development of renewable electric power sources (above all offshore and land wind farms) the compensation of reactive power gains more significance. TKFC - 3-Phase shunt reactors are disgned for the fixed value of the reactive ...read more

Lattice towers 22 kV - 400 kV

EGE Steel Structures Catalogueread more

Earthing transformers - ETR

ETR earthing transformers are used to create an artificial neutral in distribution electric networks. Typical parameters of EGE ETR earthing transformers are networks of 6, 10, 15, 20, 35 kV and rated power from 200 to 5000 kVA wiring scheme Zn, ZNyn 11 or other variants based on customer's wishes.read more

Earthing resistors for HV networks

Earthing resistors serve connections between the neutral points of distribution network to grounds in networks operating with resistor-grounded neutral points. The purpose of the resistor-grounded neutral is to dampen overvoltage during ground faults and provide sufficient current values for protection, ...read more

Auxiliary resistors

Resistors for increasing active components of fault current. Secondary resistors are used In order to improve the reliability of ground-fault directional protection instruments. The resistors enable active components of the fault current to be increased for a short time. The connection is either controlled ...read more

Ground fault arc suppression coil

Arc suppression coils are used to compensate for capacitive currents when ground faults occur on an electrical network. They are connected to the distribution network node. EGE's arc suppression coils are smoothly adjustable arc suppression coils covering: nominal network voltages from 6 kV to 110 kV ...read more

Isolated Phase Busduct (IPB)

The power series of EGE busducts can handle up to 25 kA for self-cooled IPBs and 50 kA for forced cooled IPBs as follows: Isolated phase busducts (IPB) with air insulation This type of duct is used primarily for the outlet of generator outputs at current levels as high as 28kA and voltages of 36kV. ...read more