Product description

We offer low voltage three-phase isolating and safety transformers 100VA-40kVA IP00-IP21-IP23.

Description:
Dry type three-phase transformers without protections

Standards:
EN61558-2-4 (up to 40kVA)
EN61558-2-4-6 (up to 16kVA)
UL 5085

Marks:
UL-CSA RECOGNIZED from 100VA to 25kVA
UL-CSA LISTED from 100VA to 5kVA
UL-CSA - INSULATION SYSTEM CL.F over 25kVA

Technical specifications:
Input voltage: 100-600V
Output voltage: 24-600V
Vector groups: Dyn11 (standard), Dyn5, Ynd1, Yyn0, Dd0
Test voltage: 3kV
Insulation class: B (130°C) - F (155°C)
Ambient temperature: 40°C
Protection degree: IP00
Type of termination: terminal blocks and/or bars
Enclosure color: Ral7032

Product categories

All products offered by this exhibitor

Three-phase reactors

We offer three-phase switching reactors and filter reactors. Description: Three-phase reactors used for harmonics reduction Standards: EN 60279 EN 61558-1 parts 2-20 UL 5085read more

Low voltage transformers 41-315kVA

We offer low voltage dry type three-phase power transformers 41-315kVA IP00-IP21-IP23. Description: Dry type three-phase transformers without protections Standards: EN 60076-1 CEI 14-4 e 14-8 UL 5085 Marks: UL-CSA-INSULATION SYSTEM CL.F Technical specifications: Input voltage: 100-600V Output voltage: ...read more

Low voltage transformers 100VA-40kVA

We offer low voltage three-phase isolating and safety transformers 100VA-40kVA IP00-IP21-IP23. Description: Dry type three-phase transformers without protections Standards: EN61558-2-4 (up to 40kVA) EN61558-2-4-6 (up to 16kVA) UL 5085 Marks: UL-CSA RECOGNIZED from 100VA to 25kVA UL-CSA LISTED from ...read more

Isolating and safety transformers

We offer Isolating and safety single-phase transformers for screw or DIN bar installation. Standards: EN61558-1 parti 2-4 e 2-6 Technical specifications: Standard input voltage: 230-400±15V Standard output voltage: 12-24V; 115-115V Insulation class: ta= 40°C/B Protection degree: IP20 Insulation voltage: ...read more

Low voltage transformers 30VA-10kVA IP00

We offer Isolating transformers (secondary voltage over 50V) according to EN-61558-1 part 2-4, Safety transformers (secondary voltage up to 50V) according to EN-61558-1 part 2-6, Industrial control transformers according to EN-61558-1 part 2-2, Industrial control transformer UL-CSA up to 5kVA General ...read more