Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Homepage>Exhibitors & Products >S4AO - module of 4 analog outputs

S4AO - module of 4 analog outputs

Logo S4AO - module of 4 analog outputs

Product description

Specifications:

- conversion of RS-485 MODBUS data into standard signals in 4 channels (current 0/4...20 mA or voltage 0...10 V)
- two independent communication ports (possibility to work as Master/Slave)
Master Modbus function dedicated to read out data from other RS-485 devices and scaling to analog value
Slave Modbus function to set the signal on analog outputs
Meter configuration through miniUSB with free eCon software (for S4AO module power supply is not required)

All products offered by this exhibitor

Premiere

KS5 - SYNCHRONIZATION METER

Synchronization meter KS5 has been designed for automatic switching of three-phase generators for parallel operation with the grid or with other generators with rated frequency of 50 or 60 Hz. Product characteristics: - Clear data visualization thanks to color graphic display 3.5'' TFT (separately for ...read more

Premiere

HT20 - TEMPERATURE & HUMIDITY MONITOR

HT20 monitor has been designed to measure, monitor and record temperature and humidity. It is a perfect solution for any facilities where monitoring and recording such values are very important for the accuracy of the whole process e.g.: in server rooms, drug and food warehouses, laboratories, museums ...read more

N100 power network analyzer

Specifications: measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems measurement and visualization of more than 40 energy parameters U/I harmonics measurement up to 51st programmable number of pages and selection of displayed quantities on each of the 20 pages configurable ...read more

Multimeters and clamp-on meters

NC14 AC/DC power clamp-on meter NC14 clamp-on meter measures, calculates and displays the most important electrical parameters of single and three-phase networks. It also has a multimeter function that allows to measure resistance, circuit continuity and diodes. NC12 AC/DC clamp-on meter NC12 clamp-on ...read more

P30H - transducer of d.c. parameter

Programmable input DC parameters current via shunts +/- 150mV voltage 0...12/48/100/250V or 0...600/1000V with additional resistor Output: 1 x analog 0/4...20mA or 0...10V 1 x relay, optionally changeable to 0/4...20mA or 0...10V analog output 1 x additional relay, optionally changeable to 0...24V d.c. ...read more

P30P power network transducer

Specifications: - measurement in 1 or 3-phase power network,in balanced systems - measurement and visualization of 30 energy parameters - configurable analog and alarm outputs - archiving up to 16 parameters on SD card or in the internal memory of 8GB (optional) - RS-485 interface and optional Ethernet ...read more

Universal transducer of temperature and standard signals P30U

P30U transducer is designed to convert temperature, resistance, standard voltage and current signals into a standard DC voltage or DC current signal. The output signal is galvanically isolated from the input signal and the power supply. P30U has programmable measurement and auxiliary functions. Parameters ...read more

LCT series - current transformers

3-phase current transformers with round conductor - LCTP series Current transformers LCTS series with split core - LCTS series Current transformers with primary winding - LCTM series Current transformers with round conductor - LCTB series Current transformers with round conductor - LCTR seriesread more

Shunts

Voltage drop: 60 mV, 150 mV, 50 mV, 75 mV, 100 mV Rated current: 1 A...15 kA (1; 1.5; 2.5; 4; 6 and their decimal multiples) Accuracy class: - 0.2 for ranges 1 A...2.5 kA - 0.5 for ranges 3 kA...15 kA All shunts from 1...25 A are fixed on insulating basis with the possibility to be mounted on a DIN ...read more

N21 - universal digital meter

Specifications: - universal measuring input (temperature and standard signal measurement) - universal supply voltage from 24 up to 230 V a.c./d.c. - relay alarm output - supply of object transducers 24 V d.c. - OLED display - meter configuration through miniUSB with free eCon softwareread more

NP40 - portable power quality analyzer

Specifications: measurement in 1- and 3-phase, 3- or 4-wire balanced or unbalanced systems, portable design, working with current clamp power quality analysis parameters and events archiving in internal memory of 8GB Ethernet interface and USB graphic color displayread more

S4AI - New module of 4 analog inputs

S4AI is a module of 4 analog inputs dedicated to convert standard signals (current, voltage, temperature, resistance) into digital RS-485 signal with Modbus protocol. The input signals are divided into 2 sets of 2 inputs, which are isolated from one another. RS-485 and USB ports are isolated from input ...read more

S4AO - module of 4 analog outputs

Specifications: - conversion of RS-485 MODBUS data into standard signals in 4 channels (current 0/4...20 mA or voltage 0...10 V) - two independent communication ports (possibility to work as Master/Slave) Master Modbus function dedicated to read out data from other RS-485 devices and scaling to analog ...read more

Rail mounted 3-phase power network meter N43 - NEW

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. Features: 1. The measurement of: - rms values of voltage and current, - active, reactive and apparent power, - active, reactive energy, - power factors, - frequency - THD 2. Indications ...read more

Programmable transducer of 1-phase power network parameters P41

Programmable transducer P41 type is destined for conversion into analog or digital signals 1-phase network parameters. P41 characteristics: - measurement of 1-phase network parameters: U, I, f, P, Q, S, PF, tg j , j , Ep, Eq - universal input 1 A or 5 A, 100 V or 400 V - programmable analog output ...read more

RE92 controller - dual loop - for industry purpose

RE92 is an advanced dual loop controller for industrial use. It was designed for demanding industrial applications. RE92 can control two controlled objects independently or control two physical values in one object (e.g. in the two-zone furnaces). Thanks to the universal measuring inputs, it can be used ...read more

3-phase transducer of power network parameters - P43 type

P43 is destined for the conversion of 3-phase, 3 or 4-wire power network parameters, in balanced or unbalanced systems. Inputs signals: - current: 1A or 5A - voltage: 100V or 400V 2 analog outputs, 2 relay outputs (signaling measured quantity overflows), Pulse output (control of 3-phase active ...read more