Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Homepage>Exhibitors & Products >Safety Insulation Transformers according EN 60601-1

Safety Insulation Transformers according EN 60601-1

Thalheimer Transformatorenwerke

Exhibitor details
Logo Safety Insulation Transformers  according EN 60601-1

Product description

Insulatin transformers save the insolation connected devices from
mains circuit. By the special construction behind EN 60601-1 they
are appropriate for medical technology. The devices has a grounded
protection coil and a potential equalization-pin according DIN 5710/
VDE 0107.
The transformers are constructed very strongly and has a closed
housing from sheet metal. Three groups of power are available.
The output currents are 1,9 amps, 4,0 amps and 6,0 amps. The
devices of 4,0 amps exists in different variants for input and output
connections.
The necessary protection exist on input and output these devices
with fuse. Additional has the torroid transformers a temperatur-fuse.
Devices with output current 4 amps are produced for 4 differently
versions.
230 / 230 / 4 G

All products offered by this exhibitor

Line voltage regulators - ENR / DNR / PNR / MNR

Line-voltage regulators are technological items which are very useful for the user and which, from the first idea up to the final product, have been thoroughly designed and tested by us with a view to achiving the highest possible economy. We offer you a series of powerful and useful line-voltage regulators, because ...read more

Cathodic protection rectifiers - SG

The Cathodic protection rectifierts of type SG offer numerous applications especially on the field of cathodic protection against corrosion. These variable DC power supplies for high carrying capacities are also useful in laboratories, schools, workshops etc.read more

High voltage tester - HS

The development of the series HS 0100 ist based on approved high voltage technics. Various types allow an effective use in many different fields. The high voltage testers are suitable specially for proving the electrical safety of electrical components, devices, apparatuses and equipment in industry ...read more

Single phase regulating autotransformers - ESS

safety qualities IP00 heat resistance class B max. ambient temperature +45 deg C test voltage winding shaft 4kV~ frequency 50/60 Hz angle of rotation 320°read more

Three phase toroidal regulating autotransformer - DSS

safety qualities IP00 heat resistance class B max. ambient temperature +45 deg C test voltage winding shaft 4kV~ frequency 50/60 Hz input voltage 3x400Vread more

cased regulating transformers - LTS

cased regulating transformers - LTSread more

Safety Insulation Transformers according EN 60601-1

Insulatin transformers save the insolation connected devices from mains circuit. By the special construction behind EN 60601-1 they are appropriate for medical technology. The devices has a grounded protection coil and a potential equalization-pin according DIN 5710/ VDE 0107. The transformers are constructed ...read more

Stored items

0

Server communication error: Item could not be saved.