Advertisement
HANNOVER MESSE 2018, 23 - 27 April
Homepage>Exhibitors & Products >SIL-V Voltage & Frequency / Synchronism

SIL-V Voltage & Frequency / Synchronism

Relays for transformers or electrical machines. HV,MV, LV. Islanding.

Fanox Electronic

Exhibitor details
Logo SIL-V Voltage & Frequency / Synchronism
Logo SIL-V Voltage & Frequency / Synchronism

Exhibition stand

Hall 12, Stand F03

Contact(s)
Ms. Pilar Martinez
Marketing
Send E-mail
Fax: +34 944 710 592

Product description

Main applications: Cogeneration & Loss of Mains (Islanding) detection
For transformers or electrical machines. HV, MV and LV distribution systems and for decoupling, load shedding and loss of main (islading) protection.
Auxiliary power supply (24-110 Vdc / 48-230 Vac).
Protection functions: 27(2), 27V1, 59(2), 59V2, 59N(2), Rate of change of voltage, 74TCS, BF, 52, 79, 81O/U(4), 81R(2), 86, 78, 25.
5 attempts of reclosing with 79 protection function (Recloser).
Synchronism check: Voltage differences, frequency slip, angle differences, DLDB, DLLB, LLDB. (Function 25)
Direct signalling/control of function 52 (Circuit breaker) and function 79 (Recloser).
5 oscillographic records, 20 fault reports and non-volatile RAM memory: stores 200
events without power supply thanks to its internal RTC (Real Time Clock).

Loss of Mains (Islanding) detection
Loss of Mains (Islanding) occurs when part of the public utility network loses connection with the rest of the system. If this situation is not detected, then the generator could remain connected, causing a safety hazard within the network.
Automatic reconnection of the generator to the network may occur causing damage to the generator and the network.
SIL-V protection relay detects this situation thanks to its voltage and frequency functions focused on the Rate of change of frequency (ROCOF) method.

Product website

All products offered by this exhibitor

SIA-B OC&EF Self-powered Relays

With Specific CTs. Stores up to 100 events and 4 fault reports in non-volatile RAM memory. With USB front port for communication with PC and monitoring. Test menu allows the trip circuit to be tested before the transformation center is powered up. PROTECTIONS: 50 Phase instantaneous overcurrent 51 Phase ...read more

SIA-C OC&EF Relay / Self-powered

Self-Powered Relay with standard CTsread more

SIL-D Overcurrent & Directional Relay

Overcurrent and Directional Earth Fault Protection Relayread more

SIC-A Redundancy Protocols Gateway

Redundancy Protocols Gateway (PRP/HSR) - Smart Grid Communicationread more

SIL-V Voltage & Frequency / Synchronism

Relays for transformers or electrical machines. HV,MV, LV. Islanding.read more

Earth Leakage Protection Relay

D30 Superimmunized MULTIRANGE RELAY 22,5 mmread more

SIL-G Protection Relay

Generator Protection Relay for Primary Distributionread more

Surge Protection Devices VP Series

The VP range of products protect electrical equipment and installations against transient overvoltage that may arise in the electrical supply. Besides, the VP range can be classified into 3 different types (C, B, B+C) which provide the highest protection level in order to prevent damages in the electrical ...read more

Control and Protection PANELS

for Submersible Pumps - Without Level Electrodesread more

SELF POWERED Protection Relays for T&D

«Why is Fanox the leader manufacturer of self powered relays all over the world?" Main advantages over other brands: High electromagnetic compatibility makes SIA relays the safest relays in the market, minimun guarantee period 5 years. Standard CTs /1A or /5A can be used saving money. Required burden ...read more

PBM Motor Management System

PBM Motor Management Systemread more

Stored items

0

Server communication error: Item could not be saved.